Industrial Water Chiller System
Industrial Water Chiller System

Industrial Water Chiller System

Price 350000 INR/ Piece

MOQ : 1 Piece

Industrial Water Chiller System Specification

  • Type
  • Industrial Water Chiller System
  • Material
  • Mild Steel (MS)
  • Power
  • 5 HP
  • Power Source
  • Electric
  • Voltage
  • 220-440 V
  • Capacity
  • 5 TR (Tons of Refrigeration)
  • Loading Capacity
  • 5 Ton
  • Automatic Defrost Operation
  • Yes
  • Operating Temperature
  • 5C to 30C
  • Temperature Range
  • -5C to 35C
  • Dimension (L*W*H)
  • 1200 x 900 x 1100 mm
  • Weight (kg)
  • 250 kg
  • Color
  • Green / Black
  • Display
  • LED / Digital Display
  • Refrigerant Used
  • R22 / R407C / R134a
  • Condenser
  • Air-Cooled Finned Tube
  • Usage/Application
  • Industrial Process Cooling
  • Water Flow Rate
  • 2.5 m3/hr
  • Pump Type
  • Centrifugal
  • Safety Features
  • Overload Protection, High/Low Pressure Cutoff, Water Flow Switch
  • Noise Level
  • Low Noise Operation
  • Compressor Type
  • Reciprocating / Scroll
  • Control Panel
  • Digital / Microprocessor Based
  • Phase
  • Three Phase
  • Chiller Structure
  • Floor Mounted
  • Cooling Type
  • Air Cooled
  • Insulation
  • High Density PUF
 

Industrial Water Chiller System Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 1 Piece Per Day
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

Industrial Water Chiller System About

An industrial water cooling system is designed to reject heat generated from manufacturing processes, machinery (such as air compressors, injection molding machines, and furnace jackets), or HVAC systems.

These systems generally fall into three main categories: Open-Loop Cooling Towers, Closed-Circuit Fluid Coolers, and Industrial Water Chillers.

1. Primary System Types & Comparisons

System Type Operating Principle Typical Process Outlet Temp Best For
Open-Loop Cooling Tower Process water directly contacts airflow; cooling occurs via latent heat of evaporation. $28circtext{C} text{ to } 32circtext{C}$ (depends on wet-bulb temp) Large-scale heat rejection (steel mills, power plants, chemical processes).
Closed-Circuit Cooling Tower Process fluid stays inside a sealed coil loop while spray water and air cool the exterior of the coil. $28circtext{C} text{ to } 35circtext{C}$ Applications requiring clean process loops (no scale/contamination inside equipment).
Industrial Water Chiller Mechanical refrigeration cycle (compressor, evaporator, condenser) cools water actively. $5circtext{C} text{ to } 20circtext{C}$ (or lower with glycol) Precise temperature control, high heat density, or sub-ambient cooling needs.

2. Core Technical Specifications

Thermal & Hydraulic Parameters

  • Cooling Capacity: Measured in Tons of Refrigeration (TR) ($1text{ TR} = 3.517text{ kW} = 12,000text{ Btu/hr}$) or kW/kcal/hr.

  • Flow Rates & Delta T ($Delta T$):

    • Standard design $Delta T$ (Supply vs. Return): $5circtext{C} text{ to } 10circtext{C}$ (e.g., $32circtext{C}$ inlet / $27circtext{C}$ outlet).

    • Standard flow requirement: 0.24 to 0.30 $text{m}3/text{h}$ per TR ($1 text{ to } 1.3 text{ GPM/TR}$) for cooling towers.

  • Operating Pressure: Designed for $4 text{ to } 6 text{ bar(g)}$ loop working pressure.

3. Key Equipment & Sub-Components

  1. Heat Exchangers & Structure:

    • Cooling Tower Casing: Fiber-Reinforced Plastic (FRP), Stainless Steel 304/316, or Galvanized Steel.

    • Fill Media: PVC cross-fluted film fills for clean water; splash fills for dirty/high-debris process water.

    • Plate Heat Exchangers (PHE): Gasketed or Brazed AISI 316 Stainless Steel heat exchangers used to separate process loops from raw cooling tower water.

  2. Pumping & Distribution Package:

    • Circulation Pumps: End-suction centrifugal or vertical multistage pumps in $N+1$ redundant configurations.

    • Variable Frequency Drives (VFDs): Applied to pumps and tower fans to optimize power usage based on ambient wet-bulb temperature fluctuations.

  3. Water Treatment & Filtration Sub-System:

    • Side-stream Filtration: Sand filters or disc filters handling 5%10% of total flow rate to trap suspended solids.

    • Chemical Dosing Skids: Dosing of biocide, scale inhibitors, and corrosion inhibitors to manage Cycles of Concentration (CoC) and prevent Legionella growth.

4. Utilities & Water Quality Requirements

  • Make-up Water Supply: Required for open towers to replace water lost to evaporation ($sim 1.8%$ per $10circtext{F} / 5.5circtext{C} Delta T$), drift, and blowdown.

  • Water Quality Limits:

    • pH Range: $6.8 text{ to } 8.2$

    • Total Dissolved Solids (TDS): $< 1,500 text{ to } 2,500text{ ppm}$

    • Chloride Content: $< 200text{ ppm}$ (for SS304) or $< 800text{ ppm}$ (for SS316)

    • Hardness ($text{CaCO}_3$): $< 200 - 300text{ ppm}$



Advanced Air-Cooled Technology

Our Industrial Water Chiller System employs an air-cooled, finned tube condenser for rapid and consistent heat dissipation, making it ideal for operations where water availability is limited. Its centrifugal pump ensures a steady water flow rate of 2.5 m3/hr, supporting diverse industrial cooling processes.


Intelligent Digital Control

Fitted with either a digital or microprocessor-based control panel, this system provides precise regulation of cooling parameters. The LED or digital display allows operators to monitor temperatures and system status, ensuring enhanced reliability and simple, user-friendly operation.


Reliable Operation and Safety

Equipped with essential safety mechanisms such as overload protection, high/low-pressure cutoffs, and a water flow switch, the chiller offers robust security for both the equipment and the process. High-density PUF insulation further boosts the system's thermal retention and energy efficiency.

FAQ's of Industrial Water Chiller System:


Q: How does the air-cooled chiller system function in industrial process cooling?

A: This air-cooled chiller uses a reciprocating or scroll compressor to circulate refrigerants (R22, R407C, or R134a) and a finned tube condenser to expel heat using ambient air. This process cools the water which is then circulated via a centrifugal pump to maintain desired temperatures in various industrial applications.

Q: What benefits does the digital/microprocessor-based control panel offer?

A: The digital or microprocessor control panel enables precise temperature regulation, easier troubleshooting, and real-time monitoring. This results in improved efficiency, reduced downtime, and user-friendly operation for industrial operators.

Q: When should the chiller system be serviced or maintained?

A: Routine maintenance should be performed according to the manufacturer's guidelines, typically every three to six months. Regular checks include inspecting the compressor, verifying refrigerant levels, cleaning the condenser fins, and ensuring all safety features and controls are functioning properly.

Q: Where can this water chiller system be installed?

A: Designed for floor-mounted installation, this chiller is suitable for indoor or sheltered industrial environments with stable electric supply and sufficient ventilation for air-cooled operation. Its compact footprint (1200 x 900 x 1100 mm) makes it adaptable to most factory floors.

Q: What safety features are included to protect the chiller system?

A: The chiller is equipped with overload protection, high/low pressure cutoffs, a water flow switch, and employs high-density PUF insulation to prevent thermal losses and ensure safe and efficient operation.

Q: How can this chiller system enhance industrial productivity?

A: By maintaining consistent cooling between -5C and 35C with automatic defrost and low-noise operation, the chiller ensures continuous, dependable operation. This minimizes process interruptions and helps maintain product quality in industrial production lines.

Q: What is the typical usage process for this chiller system in an industrial setting?

A: Users connect the chiller to their process equipment, set the desired temperature on the digital control panel, and initiate cooling. Water circulates continuously at a rate of 2.5 m3/hr, automatically maintaining setpoints and safeguarding performance through built-in safety systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Industrial Chiller Category

Heat Pump

Heat Pump

Price 25000 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Heat Pump

Power Source : Other, Electric

Color : Teal & Black

Voltage : 220440 V

10 TON OIL CHILLER

10 TON OIL CHILLER

Price 550000.0 INR / Piece

Minimum Order Quantity : 1 Unit

Type : OIL CHILLER

Power Source : Electrical

Color : ORANGE/IVORY

Voltage : 380420 Volt (v)

Water Chiller Plant

Water Chiller Plant

Price 325000 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Scroll Chiller

Power Source : Electrical

Color : White/Blue



Back to top